Skip to content

Configuring a run

Start with ps.Config() and change only the fields your run needs. The same nested field names work in Python, YAML and the polarism CLI.

import polarism as ps

cfg = ps.Config()
cfg.grid.nx = 64
cfg.grid.ny = 64
cfg.grid.lx = 60.0
cfg.grid.ly = 60.0
cfg.laser.laser_type = "continuous-gaussian"
cfg.laser.P0 = 0.3
cfg.laser.sigma_space = 6.0
cfg.solver.method = "ifrk-fft-cuda"
cfg.solver.tableau = "dop853"
cfg.solver.adaptive = True
cfg.solver.dt = 0.1
cfg.solver.total_time = 150.0
ps.SimulationController(cfg).run()

This runs on the CPU for 150 ps in a 60 µm by 60 µm box. The quickstart shows how to save results.

Configuration blocks

Block Sets
grid Dimension, box size and grid topology
physics Mass, interactions, rates, dispersion and spin
laser Incoherent pump
reservoir Reservoir model and component count
potential External potential and its time envelope
drive Coherent source and rotating frame
initial_condition, noise Starting field and random increments
boundary_condition Edge absorption
solver, compute_engine Time integration and CPU or GPU
result Fields, observables, visualization and storage
checkpoint, stop, sweep Restart, early stopping and sweep controls
terms Additional registered model terms

See Configuration reference for every key, default and allowed value.

Python, YAML and CLI

Save a Python config with cfg.to_yaml("run.yaml"). Load and validate it with ps.Config.from_yaml("run.yaml"). A YAML file can contain only the blocks you want to change:

grid:
  nx: 64
  ny: 64
  lx: 60.0
  ly: 60.0
laser:
  laser_type: continuous-gaussian
  P0: 0.3
  sigma_space: 6.0
solver:
  method: ifrk-fft-cuda
  tableau: dop853
  adaptive: true
  dt: 0.1
  total_time: 150.0

Run it with polarism --config run.yaml. CLI flags override file values, for example polarism --config run.yaml --grid.nx 32. Use polarism --help to see the generated flags.

Field names are exact and case sensitive: laser.P0 is valid; laser.p0 is not. Assignment in Python rejects unknown fields. Config.from_yaml also rejects unknown blocks and fields, often with a suggested spelling. Values are checked when YAML loads and when SimulationController starts; a direct Python assignment alone does not validate a value.

Units

Enter all lengths in µm, times in ps and energies in meV. Coordinates and profile widths are in µm; decay rates are in ps⁻¹. In two dimensions, density is in µm⁻² and a continuous pump P is in µm⁻² ps⁻¹. The code does no unit conversion. See Grid and physics for the model parameters.